Top Quality Cryogenic Grade 210L Liquid Oxygen Dewar Vessel For Steel Plant & Heavy Industry

Top Quality Cryogenic Grade 210L Liquid Oxygen Dewar Vessel For Steel Plant & Heavy Industry

As a low-temperature insulated pressure vessel, gas cylinders are mainly used for storing and transporting liquid oxygen, liquid nitrogen, liquid argon, liquid carbon dioxide, and liquefied natural gas, and can automatically and continuously provide gas. The gas cylinder is designed as a double-layer (vacuum) structure, with an inner liner used to store low-temperature liquids. Its outer wall is wrapped with multiple layers of insulation material, which has strong insulation performance. At the same time, the interlayer (the space between the two layers of containers) is pumped into a high vacuum, forming a good insulation system together.
Send Inquiry

Top Quality Cryogenic Grade 210L Liquid Oxygen Dewar Vessel for Steel Plant & Heavy Industry

Products Description

210L Cryogenic Storage Dewar, vertical vacuum-insulated cryogenic liquid cylinder adopting MLI multi-layer insulation technology, for static storage & self-pressurized supply of cryogenic liquid at -196℃ (LN2, LO2, LAr, LCO2). Double 304 stainless steel pressure vessel, independent vacuum jacket blocks heat conduction, convection and radiation to minimize boil-off loss. Integrated self-pressurization coil, pressure safety assembly and float liquid level monitor, to provide stable cryogenic medium supply for laboratories, cryo material testing, precision manufacturing and research institutes. Designed per pressure vessel codes, full NDT inspection, CE/ISO/TPED/DOT available, third-party performance test acceptable.

1

Product Specification

Specification DPL450-21M DPL450-21HP DPL450-Z1VHP DPL450-236MP
Geometric Volume (L) 210 210 210 236
Effective Volume (L) 189 189 189 212.4
Size(D×H)mm 中508×1716 中508×1720 中508×1720 中508×1867
Working Pressure(MPa) 1.37 2.05 2.88 1.37
Set pressure of safety value(MPa) 1.59 2.41 3.45 1.59
Set pressure of bursting discset/ Set
pressure of assistant safety value(MPa)
2.6/2.41 3.6 5.17 2.6/2.41
Evaporation rate(liquid nitrogen) ≤2.0% ≤2.0% ≤2.0% ≤1.97%
Empty weight(kg) ~131 ~148 ~173 ~141
Maximum filling weight:Liquid oxygen (kg) ~215 ~215 ~215 ~242
Maximum filling weight:Liquid nitrogen (kg) ~153 ~153 ~153 ~172
Maximum filling weight:Liquid argon (kg) ~264 ~264 ~264 ~297
Maximum filling weight:LNG(kg) ~80 / / ~90
Maximum filling weight:Liquid carbon dioxide (kg) / ~195 ~195 /
Level gauge Float type/
Capacitance
Float type/
Capacitance
Float type/
Capacitance
Float type/
Capacitance
The base style
Stainless steel-
rubber bas

Stainless steel-
rubber bas

Stainless steel-
rubber bas

Stainless steel-
rubber bas

Notice
Cryogenic liquid cylinders have an inner container and an outer container with an insulated vacuum space between them. Any abuse(dents, dropping.tip-over, etc.)can affect the integrity of the containers insulation system.DPL series containers will allow you to use a hand truck or hoist to handle these loads properly.Do not attempt to move these cylinders by any other means. While moving the cylinder, the following precautions should be observed

1.Never lay the cylinder on its side. Always ship, operate and store the unit in a vertical or upright position.

2.When loading or unloading the container from a truck,use a hand truck, lift gate, crane or parallel loading dock.Never attempt to manually lift the unit.
3.To move the container over rough surfaces, or to lift the container, attach an appropri-ated sling to the lifting points cut into the welded support posts, and use a portable lifting device that will handle the weight of the container and its contente

Features

✅ Double stainless steel vacuum insulation, low boil-off, save cryogenic gas cost

 

✅ Integrated valve manifold, self-pressurized gas supply, simple operation

 

✅ Safety valve + bursting disc dual safety protection

 

✅ Float level gauge for easy liquid volume reading

 

✅ Anti-collision base ring, anti-damage during lifting & handling

 

✅ International standard port for filling & piping

 

✅ OEM available, custom brand nameplate

Why Choose Our Cryogenic Liquid Cylinder?

1.Stable low boil-off rate, performance match global competitors with competitive price.

 

2.304 stainless steel tank, auto welding & NDT to prevent vacuum leakage.

 

3.Complete valve assembly, ready to use once received.

 

4.Multi-medium compatible for different cryogenic liquids.

Application Scenarios

✅ Gas distributor stock & resale

 

✅ Factory, laser cutting, welding, metallurgy

 

✅ Laboratory & biological sample preservation

 

✅ Marine, mining & construction site gas supply

 

✅ Food quick-freezing, chemical & electronics cryogenic application

Packing & Shipping

Cryogenic Storage Dewar

Export packing: fumigated wooden box / heavy steel frame package, steel frame recommended for sea anti-shock. Valves packed separately with foam, tank wrapped anti-rust film. Full shipping mark & hazard label. LCL & FCL available, ship from Shanghai, Ningbo, Qingdao. Loading photos available.

After Sales Service

1.12-month full machine warranty, 5-year vacuum jacket warranty.

 

2.Full English technical documents provided, remote diagnosis, operation training & safety briefing. Support drawing revision guidance, spare parts global courier. Free spare parts for non-artificial failure within warranty. Annual maintenance technical plan available, paid on-site service for overseas projects.

Troubleshooting Guide

Symptom  Possible Cause  Solution
Extensive frosting or condensation of the shell Decrease or failure of vacuum Immediately discontinue use, transfer contents, return to factory to test vacuum system
The daily evaporation rate is obviously increased Vacuum degradation, valve leakage, sealing ring aging Leak detection, replacement of seals, re-vacuum if necessary
relief valve take-off Abnormal pressure rise, overfilling, carburetor blockage Check the filling capacity (≤ 90%), check the carburetor patency, and confirm the safety valve setting value
insufficient output gas flow The carburetor is frozen and blocked, the liquid level is too low, and the valve opening is not enough Stop use and wait for the carburetor to warm up, replenish liquid nitrogen, check the opening of the valve
Level gauge reading abnormal Stagnation of float and deformation of connecting rod Tapping the level gauge catheter with a wooden stick to restore the float, replacing the level gauge if necessary;
valve handwheel difficult to turn Low temperature icing and valve stem lubrication failure Thaw valve stem with warm water (not exceeding 40 °C). Do not use open flame or knock

Unusually high pressure of tank body after transportation

Liquid nitrogen sloshing and excessive temperature during transportation

Stand for 24 hours to observe, naturally relieve pressure, and confirm the normal operation of the safety valve

 

Factory & Service Advantages

Dewar Vessel

Dewar factory

Dewar cylinder

1.In-house cryogenic pressure vessel design team, support system integration solution.

 

2.Full type test capability: hydrostatic, air tightness, vacuum, burst test.

 

3.Accept third-party lab performance sampling, English test report available.

 

4.Complete technical document: 3D drawing, P&ID, operation manual, calculation sheet, material certificate.

 

5.Global remote technical support, assist site commissioning & safety training.

Customer Visit

dewar bottle

Engineer & procurement team welcome for factory audit. Arrange production tour, hydro/vacuum witness test, prototype performance demonstration & face-to-face technical review. Interpreter & pick-up service by appointment. Certificate package, project references & test report available in advance.

FAQ

Q: What is the function of bursting disc in cryogenic storage dewar?

A: Bursting disc is secondary overpressure protection, activate when safety valve fails.

Q: How long is the pressure holding test?

A: Hydrostatic test & air tightness test follow pressure vessel code standard holding time.

Q: Can the dewar be repaired if vacuum fails?

A: Vacuum leakage inside jacket cannot be repaired; need factory re-evaluation.

Q: Is the cryogenic liquid cylinder suitable for LCO2?

A: Yes, suitable for LCO2 storage, need confirm working pressure

Q: Do you supply operation safety manual in English?

A: Yes, English manual is included in document package.

Q: What spare parts are recommended for regular maintenance?

A: Seal gaskets, pressure gauge, safety valve spare parts.

Q: What is the difference between cryogenic storage dewar and micro bulk tank?

A: 210L cryogenic dewar is portable vertical cylinder; micro bulk tank is larger stationary tank.

Contact now

 

 

 

Hot Tags: top quality cryogenic grade 210l liquid oxygen dewar vessel for steel plant & heavy industry, China top quality cryogenic grade 210l liquid oxygen dewar vessel for steel plant & heavy industry manufacturers, suppliers, 175L Cryogenic Dewar, 195L Cryogenic Dewar, cryogenic dewar, cryogenic dewar high pressure system, cryogenic dewar vapor withdrawal system, industrial cryogenic dewar