Vacuum Insulated 210L Cryogenic Liquid Oxygen Dewar Vessel for Laboratory & Research Gas
Products Description
210L Cryogenic Storage Dewar, vertical vacuum-insulated cryogenic liquid cylinder adopting MLI multi-layer insulation technology, for static storage & self-pressurized supply of cryogenic liquid at -196℃ (LN2, LO2, LAr, LCO2). Double 304 stainless steel pressure vessel, independent vacuum jacket blocks heat conduction, convection and radiation to minimize boil-off loss. Integrated self-pressurization coil, pressure safety assembly and float liquid level monitor, to provide stable cryogenic medium supply for laboratories, cryo material testing, precision manufacturing and research institutes. Designed per pressure vessel codes, full NDT inspection, CE/ISO/TPED/DOT available, third-party performance test acceptable.

Product Specification
| Specification | DPL450-21M | DPL450-21HP | DPL450-Z1VHP | DPL450-236MP |
| Geometric Volume (L) | 210 | 210 | 210 | 236 |
| Effective Volume (L) | 189 | 189 | 189 | 212.4 |
| Size(D×H)mm | 中508×1716 | 中508×1720 | 中508×1720 | 中508×1867 |
| Working Pressure(MPa) | 1.37 | 2.05 | 2.88 | 1.37 |
| Set pressure of safety value(MPa) | 1.59 | 2.41 | 3.45 | 1.59 |
| Set pressure of bursting discset/ Set pressure of assistant safety value(MPa) |
2.6/2.41 | 3.6 | 5.17 | 2.6/2.41 |
| Evaporation rate(liquid nitrogen) | ≤2.0% | ≤2.0% | ≤2.0% | ≤1.97% |
| Empty weight(kg) | ~131 | ~148 | ~173 | ~141 |
| Maximum filling weight:Liquid oxygen (kg) | ~215 | ~215 | ~215 | ~242 |
| Maximum filling weight:Liquid nitrogen (kg) | ~153 | ~153 | ~153 | ~172 |
| Maximum filling weight:Liquid argon (kg) | ~264 | ~264 | ~264 | ~297 |
| Maximum filling weight:LNG(kg) | ~80 | / | / | ~90 |
| Maximum filling weight:Liquid carbon dioxide (kg) | / | ~195 | ~195 | / |
| Level gauge | Float type/ Capacitance |
Float type/ Capacitance |
Float type/ Capacitance |
Float type/ Capacitance |
| The base style | Stainless steel- rubber bas |
Stainless steel- rubber bas |
Stainless steel- rubber bas |
Stainless steel- rubber bas |
Notice
Cryogenic liquid cylinders have an inner container and an outer container with an insulated vacuum space between them. Any abuse(dents, dropping.tip-over, etc.)can affect the integrity of the containers insulation system.DPL series containers will allow you to use a hand truck or hoist to handle these loads properly.Do not attempt to move these cylinders by any other means. While moving the cylinder, the following precautions should be observed
1.Never lay the cylinder on its side. Always ship, operate and store the unit in a vertical or upright position.
2.When loading or unloading the container from a truck,use a hand truck, lift gate, crane or parallel loading dock.Never attempt to manually lift the unit.
3.To move the container over rough surfaces, or to lift the container, attach an appropri-ated sling to the lifting points cut into the welded support posts, and use a portable lifting device that will handle the weight of the container and its contente
more details

Features
✅Vacuum process: long high-vacuum pumping & degassing, stable vacuum jacket, 5-year vacuum warranty.
✅ Welding: auto cryogenic welding, 100% RT/UT NDT on weld seam to avoid micro leakage.
✅Safety redundancy: safety valve + bursting disc, comply with PED pressure vessel standard.
✅Degreasing option: oil-free degreasing for LO2 dedicated version for oxygen service safety.
✅ Consistent performance: boil-off tested individually for every dewar, test data report supplied, not theoretical value.
Why Choose Our Cryogenic Liquid Cylinder?
1.Stable low boil-off rate, performance match global competitors with competitive price.
2.304 stainless steel tank, auto welding & NDT to prevent vacuum leakage.
3.Complete valve assembly, ready to use once received.
4.Multi-medium compatible for different cryogenic liquids.
Application Scenarios
| Industry | Specific Use |
|---|---|
| Laser Cutting | Liquid oxygen/liquid nitrogen as auxiliary gas, 210L Duva tank 2.3 MPa equipped with medium and heavy plate stainless steel, carbon steel cutting gas supply requirements |
| Metal Welding | Liquid argon is used as welding shielding gas, and continuous gas supply by built-in vaporizer replaces argon cylinder group |
| Medical Refrigeration | Liquid nitrogen is used for cryotherapy in dermatology, cryotherapy of surgical instruments, and short-term storage of biological samples |
| Scientific Research | Laboratory liquid nitrogen replenishment, low temperature physical experiment, material cryogenic treatment |
| Gas Distribution | Gas suppliers replace high-pressure cylinders with 210L Duva tanks for "liquid distribution", and the single distribution volume is equivalent to more than 18 cylinders |
| Food Processing | Liquid Nitrogen Quick Freezing and on-site Refrigeration of Food Cold Chain Transportation |
| Livestock Breeding |
Liquid nitrogen storage of frozen semen and embryos, demand for 210L capacity breeding bull stations, and large-scale farms |
How to Select dewar cylinder?
Selection logic: medium property → operating pressure → heat load → refilling cycle → transport regulation.
1. Medium: filling density varies for different cryogenic liquids, filling factor must comply with pressure vessel code; LO2 service requires oil-free degreasing treatment.
2.Pressure grade: 1.4MPa for indoor static storage, low gas flow; 2.3MPa for continuous discharge & higher outlet pressure.
3.Heat load evaluation: ambient temperature, ventilation & sunlight affect boil-off rate. Enhanced insulation for high-temperature environment.
4. Transport requirement: DOT certified version required for cross-region mobile application, comply with IMDG.
5.Monitoring upgrade: 4-20mA digital level & pressure transmitter optional for DCS integration in remote project.
Submit working condition sheet, we can provide thermal balance simulation for boil-off prediction.
Packing & Shipping

Packaging standard:
1.Each Dovite tank is separately loaded with a fumigation-free wooden box or a custom-made steel frame pallet, and the tank body is filled with shock-absorbing foam/rubber pads to prevent displacement and collision during transportation.
2.Protective caps are installed on all valve joints of the tank to prevent damage and foreign objects from entering during transportation.
3.The accompanying document bag (including material book, inspection report, operation manual) is fixed in the designated position in the box.
Transportation Requirements:
1.When transporting, it should be placed upright, and the tank body should be fixed in the compartment or container with straps, and it should not be inverted or tilted.
2.When the empty tank is transported, the valve is slightly opened or a relief-type protective cap is used to prevent abnormal internal pressure caused by temperature changes.
3.When filling liquid nitrogen for transportation, ensure that the liquid level does not exceed 90% of the nominal filling amount, leaving gas phase space.
4.Avoid direct sunlight and high temperature, and the compartment temperature is recommended to be controlled within the range of-20 °C to + 50 °C.
After Sales Service
1-year machine warranty, 5-year vacuum warranty. Online English technical support, spare parts global courier. Free spare parts for non-artificial damage within warranty. English operation manual. Bulk distributors get dedicated aftersales contact person.
Factory & Service Advantages



1.In-house cryogenic pressure vessel design team, support system integration solution.
2.Full type test capability: hydrostatic, air tightness, vacuum, burst test.
3.Accept third-party lab performance sampling, English test report available.
4.Complete technical document: 3D drawing, P&ID, operation manual, calculation sheet, material certificate.
5.Global remote technical support, assist site commissioning & safety training.
Customer Visit

Overseas distributors welcome to visit factory, check production line & stock, discuss agency & distribution cooperation. Reception & interpreter available by appointment.
FAQ
Q: Can I use this cryogenic liquid cylinder outdoors?
A: Yes, avoid direct long-time strong sunlight exposure, recommend sunshade.
Q: What is the function of bursting disc in cryogenic storage dewar?
A: Bursting disc is secondary overpressure protection, activate when safety valve fails.
Q: How long is the pressure holding test?
A: Hydrostatic test & air tightness test follow pressure vessel code standard holding time.
Q: Is the cryogenic liquid cylinder suitable for LCO2?
A: Yes, English manual is included in document package.
Q: Can you perform performance witness test at factory?
A: Yes, welcome witness test by your engineer or third-party inspector.
Q: Can this 210L liquid nitrogen dewar be refilled on site?
A: Yes, refilling by qualified cryogenic gas operator with filling station.
Hot Tags: vacuum insulated 210l cryogenic liquid oxygen dewar vessel for laboratory & research gas, China vacuum insulated 210l cryogenic liquid oxygen dewar vessel for laboratory & research gas manufacturers, suppliers, cryogenic dewar, cryogenic dewar for gas storage, cryogenic dewar for industrial use, cryogenic dewar skid system, industrial cryogenic dewar, portable cryogenic dewar